DEM resampling
A size function from fine DEMs (e.g. 3 m CUDEM tiles) is computed on
every DEM pixel, although the mesh is never finer than hmin. Most of
the time then goes into pixels far smaller than any element.
resampling_factor computes the sizes on coarser pixels instead. It
is off by default, so existing scripts give the same size functions.
The factor is a fraction of hmin: with hmin=50 m, 1.0 gives
50 m pixels, 0.5 25 m and 0.25 12.5 m. DEMs are never resampled
to pixels finer than their own, so a factor finer than a tile leaves
that tile as it is.
Size function grid
The collector’s factor sets the grid the sizes are computed on. Each
input DEM is resampled once, after it is clipped to base_shape:
import ocsmesh
hfun = ocsmesh.Hfun(
tile_paths, hmin=50, hmax=3000, method='exact',
base_shape=domain, base_shape_crs='EPSG:4326',
resampling_factor=0.5, # 25 m grid
resampling_method='average')
resampling_method is a rasterio.enums.Resampling name:
'average' (default), 'min' (deepest value: keeps narrow channels
and creeks connected), 'max', 'bilinear', 'nearest', …
Nodata pixels are left out when pixels are combined.
Resolution per refinement
Contours, channels, flow limiters and constant values (depth bands)
take their own resampling_factor and resampling_method, for the
DEM they are computed from:
None(default)the collector’s value, i.e. the size function grid
'native'the DEM’s own pixels
- a number
factor * hminpixels
# contours traced on the full DEM
hfun.add_contour(level=0, expansion_rate=0.001, target_size=200,
resampling_factor='native')
# channels detected on hmin/8 pixels
hfun.add_channel(level=0, width=2000, target_size=500,
resampling_factor=0.125)
# depth bands from a 50 m DEM
hfun.add_constant_value(value=500, lower_bound=-20, upper_bound=-5,
resampling_factor=1.0)
Detected contours and channels are lines and polygons, so they are applied to the size function grid whatever DEM they come from. Flow limiters and constant values computed on finer pixels than the grid are reduced onto it keeping the smallest size in each cell. Constraints, patches and line features are always computed on the grid.
Resampling applies to the exact method, to DEMs given to the
collector as rasters or file paths, and works the same in every
execution mode (see Parallel and MPI execution).
The New Jersey factors: 'optimum'
resampling_factor='optimum' on the collector uses the factors found
on the New Jersey test domain (below), with hmin / 2 as the
coarsest grid:
computed on |
factor, method |
|---|---|
the grid (depth bands, constraints, region, patch, features, Courant) |
|
|
|
|
|
|
not covered (slopes on the DEM’s own pixels, sizes still on the grid; see below) |
|
the grid |
A refinement’s own resampling_factor or resampling_method still
wins, coarser ones included. These values come from one domain (3 m
CUDEM tiles, hmin=50 m, hmax=3000 m), so the collector warns
that other domains, DEMs or hmin/hmax may need other factors:
check the resulting mesh.
'optimum' does not cover flow limiters: no resampling setting kept
their sizes on New Jersey (see below), and adding one to a resampled
grid warns. Leave resampling_factor unset when using
add_subtidal_flow_limiter.
hfun = ocsmesh.Hfun(tile_paths, hmin=50, hmax=3000,
resampling_factor='optimum')
hfun.add_channel(level=0, width=2000, target_size=500) # at 0.125
hfun.add_contour(level=0, target_size=200,
expansion_rate=0.001) # at 0.5, 'min'
Choosing a factor
Tests on a New Jersey domain (3 m CUDEM, hmin=50 m, serial runs
compared with the same run without resampling) give a starting point;
the right values depend on the DEMs and the refinements:
constant values (depth bands), region constraints, patches, line features, the Courant constraint and
add_topo_func_constraintbarely change up to1.0(10 to 100 times faster, mesh nodes within 1%);constraints with a
rate:0.5withresampling_method='min'(130 times faster, nodes within 2%), or0.25with'average';constraints without a
ratefollow every pixel at the edge of their depth range, so the size function changes at any factor, but the mesh does not (nodes within 2% at1.0);contours:
0.5with'min'kept the size function and the line within 63 m (95th percentile), 20 times faster;'native'contours are exact but cost most of the original run time;channels:
resampling_factor=0.125onadd_channelfound the channels of the full DEM with an overlap (intersection over union) of 0.97 (0.25: 0.94). Detection is most of the cost, so a coarse grid comes free: with the collector at1.0the run was 16 times faster in serial and 18 times faster with MPI, and the mesh had 6% fewer nodes.'min'detects channels that are not there;flow limiters: not yet. Slopes from a coarse DEM are too gentle (40% fewer nodes), and slopes from the native DEM reduced to a coarse grid keep the smallest size in each cell, which refines far too much. Leave the collector without
resampling_factorwhen usingadd_subtidal_flow_limiter.